Cat C32 ACERT Generator Set (IMO II)

  • Exterior View

Cat C32 ACERT Generator Set (IMO II)

Minimum Rating 550 eKW (688 kVA)
Maximum Rating 940 ekW (1175 kVA)
Frequency 50 Hz or 60 Hz
Speed 1500 rpm (50 hz) or 1800 rpm (60 hz)
Emissions/Fuel Strategy IMO II
Engine Model Vee 12, 4-Stroke-Cycle Diesel
Generator Set Specifications
Minimum Rating 550 eKW (688 kVA)
Maximum Rating 940 ekW (1175 kVA)
Frequency 50 Hz or 60 Hz
Speed 1500 rpm (50 hz) or 1800 rpm (60 hz)
Minimum Rating 550 eKW (688 kVA)
Maximum Rating 940 ekW (1175 kVA)
Frequency 50 Hz or 60 Hz
Speed 1500 rpm (50 hz) or 1800 rpm (60 hz)
Emissions/Fuel Strategy IMO II
Generator Set Configurations
Emissions/Fuel Strategy IMO II
Engine Specifications
Engine Model Vee 12, 4-Stroke-Cycle Diesel
Aspiration Twin Turbocharged-Aftercooled
Bore 6 in
Stroke 6 in
Displacement 1,959 in3
Governor Type Electronic
Fuel System Diesel
Aspiration Twin Turbocharged-Aftercooled
Bore 6 in
Stroke 6 in
Displacement 1,959 in³
Governor Type Electronic
Engine Model Vee 12, 4-Stroke-Cycle Diesel
Generator Set Dimensions
Length 168 in
Width 66 in
Height 71 in
Weight (Estimated) 15,721 lb
Length 168 in
Width 66 in
Height 71 in
Weight - Estimated 15,721 lb
Generator Specifications
Frame Size 1423, 1467
Excitation permanent magnet (PMG)
Pitch 2/3
Number of Poles 4
Number of Bearings 2 roller bearings
Number of Leads 6
Insulation Class H
IP Rating Drip Proof IP 23*
Alignment Closed-coupled adapter
Wave Form Deviation - Line to Line < 3.0%
Voltage Regulator Cat® Digital Voltage Regulator (CDVR)
Voltage Regulation ± 0.5% (steady state)
Telephone Influence Factor (TIF) < 50

Emissions

IMO II comlpliant

Worldwide Support

Extensive service network of dealers; Unparalleled service from authorized marine dealers

Durability

Proven engine operating history; Performance iron with thousands of hours of validation testing for quality and durability

Reliability

60 months standard warranty

Cooling System

Heat Exchanger or Keel Cooling; Heat exchanger configurations: optional front mounted sea water pump

Aftercooling System

Separate circuit aftercooling system (SCAC): no seawater circulating through the aftercooler

  • Air Inlet System
    • Separate circuit after-cooled (SCAC)
    • Turbocharger, jacket water cooled
    • Turbocharger inlet, 152 mm (6 in) OD straight connection
  • Control System
    • If an EMCP panel or MGCP option is not chosen as optional equipment, then start/stop controls must be provided by the customer
    • Electronic diagnostics and fault logging
    • Engine Protection Mode for extended ambient conditions
    • Electronic fuel/air ratio control
  • Cooling System
    • Separate Circuit After-Cooling (SCAC) for Heat Exchanged (HEX) & Keel cooled engines
    • Jacket Water (JW) and SCAC Heat Exchangers Shell & Tube for HEX cooled engines
    • SCAC pump, gear driven
    • Jacket water pump, gear driven
    • Sea water pump, bronze impeller, gear driven, for HEX cooled engines only
    • Jacket water HEX with Sea water pump Connections: 76.2 mm (3in) ID Standard
    • 4 Bolt ANSI Flange Connection
    • Jacket water HEX without Sea water pump Connection: 2.5" hose barb connection (inlet), 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange (outlet)
    • Keel Connections: 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange Connection
    • SCAC and JW shunt tanks for maintaining proper Pump inlet pressures
  • Exhaust System
    • Water-cooled exhaust manifold & turbocharger
    • 4 Bolt 130 mm (5.12 in) diameter flanged outlet
  • Flywheels & Flywheel Housings
    • Flywheel Housing, SAE No. 0
    • Flywheel, 18 inch, 136 teeth
    • SAE standard rotation
  • Fuel System
    • Duplex Fuel Filters, Spin-on, RH service
    • Fuel connections size: Supply JIC Deg -10 (7/8 - 14), Return JIC 37 Deg -8 (3/4 -16)
    • Plate-type fuel cooler installed behind Aftercooler Shunt Tank
    • Fuel transfer pump, gear driven
    • Manual fuel priming pump
  • Generators And Generator Attachments
    • SR5 form wound
    • 2 roller bearings
    • Permanent magnet excitation
    • 4 pole, 6 leads, Series Star connected
    • Caterpillar's Digital Voltage Regulator (CDVR)
    • Marine Class H insulation, Class F temperature rise
    • Surface mounted platinum (PT100) 3-wire RTDs, 2 per phase on stator and one each on support bearings
    • Anti-condensation space heaters (2 elements - 240 VAC, 1000 Watts
    • IP23 Protection suitable for use with Fixed Water Based Local Application Fire Fighting Systems (FWBLAFFS)
    • System IV insulation for harsh environment protection
  • Lube System
    • Simplex oil filters, RH service
    • Deep sump oil pan
    • RH service oil filler locations
    • RH service dipstick
    • Oil pump, gear driven
  • Mounting System
    • Formed C-channel rails, 300mm (11.81in) height
    • Six shipped loose combined helical spring/rubber isolators for installation below package base
  • General
    • Front damper guard
    • Common electrical bonding point on HEX and KEEL cooled engines
  • Alarm And Protection
    • Remote Panels
    • MCS Controller
    • Power analyzer module
    • oil level, exhaust temperature, air starting pressure, heat exchanger pressure sensors
  • Exhaust System
    • Dry Elbows
    • Flexible Fitting
    • Flange
    • Muffler
    • Muffler Spark Arresting
    • Rain Cap
  • Air Inlet System
    • Air Inlet Cleaner
    • Closed Crankcase Ventilation
    • Air inlet adapter
  • Charging System
    • Battery Chargers, Charging Alternators
  • Control System
    • Load Sharing Attachment
  • Fuel System
    • Water Separator
  • Lube System
    • Duplex Oil Filters, Sump Pump
  • Protection System
    • Fuel and Oil Shielding
  • Starting System
    • Electric Starting Motors - Single 24 Volt
    • Air Starting Motor
    • Dual Starting Motors (Electric and Air)
    • Air Start Accessories
    • Starting Aids - JW Heaters
    • Battery Sets - 24 Volt - Dry
×