Diesel Generator Sets

3412C Generator Set

Bore
5 in
Displacement
1,649 in3
Stroke
6 in

3412C Generator Set

Bore
5 in
Displacement
1,649 in3
Stroke
6 in

3512 Generator Set

Bore
7 in
Displacement
3,161 in3
Stroke
7 in

3512 Generator Set

Bore
7 in
Displacement
3,161 in3
Stroke
7 in

3512 Generator Set

Stroke
7 in
Aspiration
TA
Fuel System
Direct Unit Injection

3512 with Upgradeable Package

Bore
170 mm (6.69 in)
Displacement
51.8 L (3161.03 in3)
Stroke
190 mm (7.48 in)

3512B (50 Hz) Generator Set

Bore
7 in
Displacement (HD)
3,574 in3
Stroke (HD)
8 in

3512B (50 Hz) India Market Only

Bore
7 in
Displacement
51.8 L (3161.03 in³)
Stroke
7 in

3512B Diesel Generator Set

Bore
7 in
Displacement (HD)
3,574 in3
Stroke (HD)
8 in

3512B Diesel Generator Set

Bore
7 in
Displacement (HD)
3,574 in3
Stroke (HD)
8 in

3512B Diesel Generator Set

Minimum Rating
1230 eKW
Maximum Rating
1500 eKW
Voltage
380 to 480 Volts

3512C Generator Set

Bore
7 in
Displacement
3,574 in3
Stroke
8 in

3512C Generator Set

Bore
7 in
Displacement
3,161 in3
Stroke
7 in

3516 Diesel Generator Set

Bore
7 in
Displacement
4,211 in³
Stroke
7 in

3516 Diesel Generator Set

Bore
7 in
Displacement
4,211 in³
Stroke
7 in

3516 Diesel Generator Set

Bore
7 in
Displacement
4,211 in³
Stroke
7 in

3516 Diesel Generator Set

Minimum Rating
1450 ekW
Maximum Rating
1750 ekW
Emissions/Fuel Strategy
Low Fuel Consumption

3516B (50 Hz) Generator Set

Bore
7 in
Displacement (HD)
4,765 in3
Stroke (HD)
8 in

3516B Generator Set

Bore
7 in
Displacement (HD)
4,765 in3
Stroke (HD)
8 in

3516B (50 Hz) India Market Only

Bore
7 in
Displacement
69 L (4210.64 in³)
Stroke
7 in

3516B Generator Set

Bore
7 in
Displacement (HD)
4,765 in3
Stroke (HD)
8 in

3516B Generator Set

Bore
7 in
Displacement (HD)
4,765 in3
Stroke (HD)
8 in

3516B Generator Set

Bore
7 in
Displacement (HD)
4,765 in3
Stroke (HD)
8 in

3516B (60 Hz) with Upgradeable Package

Height - Maximum
98 in
Length - Maximum
235 in
Width - Maximum
90 in

3516B Generator Set

Minimum Rating
1750 kVA
Maximum Rating
2275 kVA
Voltage
380 to 11000 Volts

3516B Generator Set

Minimum Rating
1640 ekW
Maximum Rating
1825 ekW
Voltage
380 to 13800 Volts

3516C Generator Set

Bore
7 in
Stroke (HD)
8 in
Aspiration
TA

3516C Generator Set

Minimum Rating
2500 kVA
Maximum Rating
2750 kVA
Voltage
380 to 11000 volts

3516C (50 Hz) with Upgradeable Package

Minimum Rating
2500 kVA
Maximum Rating
2750 kVA
Emissions/Fuel Strategy
Low Fuel Consumption

3516C Generator Set

Bore
7 in
Stroke (HD)
8 in
Aspiration
TA

3516C Tier 4 Final

Bore
7 in
Displacement (HD)
4,765 in3
Stroke (HD)
8 in

3516E Low Voltage Generator Set

Bore
7 in
Stroke (HD)
8 in
Aspiration
TA

3516E Generator Set

Minimum Rating
3000 kVA
Maximum Rating
3500 kVA
Voltage
380 to 11000 volts

3516E Generator Set

Minimum Rating
3000 kVA
Maximum Rating
3500 kVA
Emissions/Fuel Strategy
U.S. EPA Cert. Tier 2 / Low NOx

3516E Low Voltage Generator Set

Bore
7 in
Stroke (HD)
8 in
Aspiration
ATAAC

3606 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3606 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3608 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3608 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3612 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3612 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3616 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

3616 Generator Set (Medium Speed)

Bore
11 in
Displacement
1,127 in3
Stroke
12 in

C1.1 Generator Set

Bore
3 in
Displacement
69 in3
Stroke
3 in

C1.1 Generator Set

Bore
3 in
Displacement
69 in3
Stroke
3 in

C1.5 Generator Set

Bore
3 in
Displacement
91 in3
Stroke
4 in

C1.5 Generator Set

Bore
3 in
Displacement
91 in3
Stroke
4 in

C13 Generator Set

Bore
5 in
Displacement
763 in³
Stroke
6 in

C13 (50 Hz) India Market Only

Aspiration
Air to Air Aftercooled
Fuel System
MEUI™
Minimum Rating
400 kVA

C13 (50 Hz) China Non Road

Bore
5 in
Displacement
763 in³
Stroke
6 in

C13 Generator Set

Bore
5 in
Displacement
763 in³
Stroke
6 in

C13 Generator Set

Bore
5 in
Displacement
763 in³
Stroke
6 in

C15 Generator Set

Bore
5 in
Displacement
928 in³
Stroke
7 in

C15 (50 Hz) India Market Only

Bore
5 in
Displacement
928 in³
Stroke
7 in

C15 (50 Hz) China Non Road

Bore
5 in
Displacement
928 in³
Stroke
7 in

C15 Generator Set

Bore
5 in
Displacement
928 in³
Stroke
7 in

C15 Generator Set

Bore
5 in
Displacement
928 in³
Stroke
7 in

C175-16 Generator Set

Bore
9 in
Displacement
5,156 in³
Stroke
9 in

C175-16 Generator Set

Bore
9 in
Displacement
5,156 in³
Stroke
9 in

C175-16 Tier 4 Final

Bore
9 in
Displacement
5,156 in³
Stroke
9 in

C175-20

Bore
7 in
Displacement
6,456 in³
Stroke
9 in

C175-20

Bore
7 in
Displacement
6,456 in³
Stroke
9 in

C18 Generator Set

Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Minimum Rating
550 kVA

C18 Generator Set

Minimum Rating
706 kVA
Maximum Rating
850 kVA
Voltage
380 to 415 Volts

C18 Generator Set

Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Minimum Rating
550 kVA

C18 (50 Hz) India Market Only

Aspiration
Air to Air Aftercooled
Fuel System
MEUI
Minimum Rating
600 kVA

C18 Generator Set

Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Minimum Rating
455 ekW

C18 Generator Set

Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Fuel System
Electronic unit injection

C18 Generator Set

Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Minimum Rating
455 ekW

C18 Generator Set

Minimum Rating
500 ekW
Maximum Rating
750 ekW
Voltage
208 to 600 Volts

C18 Generator Set

Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Minimum Rating
455 ekW

C2.2 Generator Set

Bore
3 in
Displacement
135 in³
Stroke
4 in

C2.2 Generator Set

Bore
3 in
Displacement
135 in³
Stroke
4 in

C27 Generator Set

Bore
5 in
Displacement
1,649 in³
Stroke
6 in

C3.3 Generator Set

Bore
4 in
Displacement
201 in³
Stroke
5 in

C3.3 Generator Set

Bore
4 in
Displacement
201 in³
Stroke
5 in

C32 Generator Set

Bore
6 in
Displacement
1,959 in³
Stroke
6 in

C32 (50 Hz) India Market Only

Bore
6 in
Displacement
1,959 in³
Stroke
6 in

C32 (60 Hz)

Bore
6 in
Displacement
1,959 in³
Stroke
6 in

C4.4 Generator Set

Bore
4 in
Displacement
269 in³
Stroke
5 in

C4.4 Generator Set

Bore
4 in
Displacement
269 in
Stroke
5 in

C4.4 Generator Set

Bore
4 in
Displacement
269 in
Stroke
5 in

C4.4 Generator Set

Bore
4 in
Displacement
269 in³
Stroke
5 in

C7.1 ACERT

Bore
4 in
Displacement
428 in³
Stroke
5 in

C7.1 Generator Set

Bore
4 in
Displacement
428 in³
Stroke
5 in

C7.1 ACERT

Bore
4 in
Displacement
428 in³
Stroke
5 in

C9 Generator Set

Bore
4 in
Displacement
537 in³
Stroke
6 in

C9 Generator Set

Bore
4 in
Displacement
537 in³
Stroke
6 in

C9 Generator Set

Bore
4 in
Displacement
537 in³
Stroke
6 in

CM20C Generator Set

Genset Rating Range
985 - 1650 kWe
Engine Rating Range
1020 - 1710 kW
Emission Level Up To
World bank emission certification (Stage 2)

CM25E Generator Set

Emission Level Up To
World bank emission certification (Stage 2)
Genset Rating Range
1940 - 2910 kWe
Engine Rating Range
2010 - 3015 kW

CM32E

Mean Effective Pressure Up To
344 psi
Genset Rating Range
3085 - 4630 kWe
Engine Rating Range
3150 - 4725 kW

CM43C (Inline)

Genset Rating Range
5520 - 8290 kWe
Engine Rating Range
5640 - 8460 kW
Emission Level Up To
World bank emission certification (Stage 2)

CM43C (V-Type)

Genset Rating Range
11170 - 14890 kWe
Engine Rating Range
11400 - 15200 kW
Emission Level Up To
World bank emission certification (Stage 2)

CM46DF (Inline)

Genset Rating Range
5290 - 7930 kWe
Engine Rating Range
5400 - 8100 kW
Emission Level Up To
World bank emission certification (Stage 2)

CM46DF (V-Type)

Genset Rating Range
10580 - 14110 kWe
Engine Rating Range
10800 - 14400 kW
Emission Level Up To
World bank emission certification (Stage 2)
×