The CEM is controlled by a separate dosing module that has been integrated into the standard generator set controls for complete monitoring, protection and closed loop NOx control.
For more information on the CEM, refer to cut sheet LEHE0359.
UL 2200 / CSA - Optional
UL 2200 listed packages
CSA Certified
Certain restrictions may apply.
Consult with your Cat® Dealer.
Air Inlet
Air cleaner
Exhaust System
Exhaust manifold - dry
Cooling
Package mounted radiator
Fuel System
Fuel cooler
Engine fuel transfer pump
Primary fuel filter w/integral water separator and secondary filter
Fuel priming pump
Flexible fuel lines
Exhaust
Exhaust flange outlet
Fuel
Primary fuel filter with integral water separator
Fuel priming pump
Secondary fuel filters
Generator
Matched to the performance and output characteristics of Cat engines
IP23 Protection
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Power Termination
Busbar
Lube System
Oil filter and dipstick
Lubricating oil
Oil drain lines with valve; piped to edge of base
Fumes disposal, piped to front of radiator
Oil cooler
Control Panel
GCCP Genset Controller
Mounting
Rubber vibration isolators
Protection System
Safety shutoffs for: Higher water temperature - Overspeed - Low oil pressure
Cooling System
Thermostats and housing, full open temperature 92 deg C (198 deg F)
Coolant level sensor
Coolant level sight gauge
Fan and belt guards
Jacket water pump, gear driven, centrifugal
Coolant drain line with valve; terminated on edge of base
Caterpillar extended life coolant
Starting/charging
24V, 45 Amp Charging alternator
24 Volt electric starting motor
24 volt starting motor
Batteries
General
Paint - Caterpillar yellow except rails and radiators gloss black
Paint, Caterpillar yellow
Operation and maintenance manual pack and OMM storage compartment
Parts book
Vibration damper
Control System
Local annunciator
Programmable Input / Output: 2 programmable digital inputs - 2 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C)
Suitable for use as service equipment label
Separation plate
Control panel mounting location
Breaker box mounting location
Optional external analog input
Remote annunciators
GCCP 1.2
Communications: Customer data link (RS485 Modbus RTu) - Serial annunciator module data link for local and remote annunciator IVR - Integrated Voltage Regulation (Digital) - EM10 Excitation Module
Digital indication for: rpm - DC volts - operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature (C or F) - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase & average) - kVA (per phase & average) - kVAr (per phase and average) - kW-hr (total) - kVAr-hr (total)
Programmable protective relaying functions: Generator phase sequence - Over/under voltage (27/59) - Over/under frequency (81 o/u) - Overcurrent (50/51)
Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - high coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level
Control panel options: Dust proof control panel - volt free contact - Device server - Ground fault relay