CG260 Gas Generator Set

Overview
Maximum Continuous Rating
3000 ekW @1.0pf
Fuel Type
Natural Gas, Coal Gas
Maximum Electrical Efficiency
43.90%

Generator Set Specification

Maximum Continuous Rating
3000 ekW @1.0pf

Generator Set Specifications

Fuel Type
Natural Gas, Coal Gas
Maximum Electrical Efficiency
43.90%
Maximum Standby Rating
3333 ekW
Frequency
60 Hz
RPM
900 rpm

Engine Specifications

Engine Model
CG260-12
Displacement
12,443 in³
Aspiration
TA
Bore
10 in
Stroke
13 in

Generator Set Dimensions

Length
315 in
Width
105 in
Height
110 in
Dry Weight - Genset
89,617 lb

High Reliability

  • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
  • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
  • Higher reliability and lower maintenance costs due to open combustion chamber technology
  • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
  • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
  • Higher reliability and lower maintenance costs due to open combustion chamber technology

High Availability, High Profitability

  • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
  • More profit for your plant
  • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
  • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
  • More profit for your plant
  • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)

Optimized Lubrication Consumption

  • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
  • Improved components reduce lube oil consumption
  • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products
  • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets
  • Improved components reduce lube oil consumption
  • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products
  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • flange connections for JW inlet and outlet
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • Exhaust waste gate for the CG132B-16
    • Closed crankcase ventilation system
  • Fuel System
    • Independently controlled cylinder monitoring and ignition system
    • Electronic fuel metering valve
    • Pre-chamber spark plugs
  • Generator
    • Busbar connections
    • closed-coupled generator result in no torque transmission to the base frame
    • Anti-condensation space heater
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • grid code generator
    • Winding temperature detectors
  • Starting/charging
    • 24V starting motors
    • Battery disconnect switch
  • General
    • Crankshaft vibration damper and guard
  • Cooling
    • CHP skid
×