CG260-16 Gas Generator Set

  • Exterior View

CG260-16 Gas Generator Set

Continuous Rating 4300 / 4000 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 10%)
Maximum Electrical Efficiency 44.1 / 43.8%
Maximum Standby Rating 4500 ekW
Frequency 50 / 60 Hz
RPM 1000 / 900 rpm
Generator Set Specifications
Continuous Rating 4300 / 4000 ekW @1.0pf
Fuel Type Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 10%)
Maximum Electrical Efficiency 44.1 / 43.8%
Maximum Standby Rating 4500 ekW
Frequency 50 / 60 Hz
RPM 1000 / 900 rpm
Engine Specifications
Engine Model CG260-16
Displacement 16,586 in³
Aspiration TA
Bore 10 in
Stroke 13 in
Generator Set Dimensions
Length 371 in
Width 110 in
Height 133 in
Dry Weight - Genset 117,505 lb

High Reliability

  • Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
  • State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
  • Higher reliability and lower maintenance costs due to open combustion chamber technology

High Availability, High Profitability

  • Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
  • More profit for your plant
  • Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
  • Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)

Optimized Lubrication Consumption

  • Savings of up to 4,000 liters of lube oil per year compared to comparable gensets<li>
  • Improved components reduce lube oil consumption<li>
  • Lower operating costs due to 30% lower lube oil consumption in comparison to similar products<li>
  • Air Inlet
    • One-element single-stage air cleaner with enclosure and sevice indicator
    • Turbocharger with a water-cooled bearing case for all cylinder
  • Control Panels
    • TEM (Total Electronic Management)
  • Cooling
    • flange connections for JW inlet and outlet
    • Jacket water and SCAC thermostats
    • Electrical jacket water and aftercooler coolant pump
  • Exhaust
    • Exhaust waste gate for the CG260-16
    • Closed crankcase ventilation system
  • Fuel System
    • Electronic fuel metering valve
    • Independently controlled cylinder monitoring and ignition system
    • Pre-chamber spark plugs
  • Generator
    • Busbar connections
    • Closed-coupled generator result in no torque transmission to the base frame
    • Reactive droop
    • 3-phase sensing and KVAR/PF control
    • Grid code generator
    • Anti-condensation space heater
    • Winding temperature detectors
  • Starting/charging
    • Compressed air engine start
  • General
    • Crankshaft vibration damper and guard
  • Cooling
    • CHP skid
×