CG260-16 Gas Generator Set
Continuous Rating |
4300 / 4000 ekW @1.0pf |
Fuel Type |
Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 10%) |
Maximum Electrical Efficiency |
44.1 / 43.8% |
Maximum Standby Rating |
4500 ekW |
Frequency |
50 / 60 Hz |
RPM |
1000 / 900 rpm |
Generator Set Specifications
Continuous Rating |
4300 / 4000 ekW @1.0pf |
Fuel Type |
Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 10%) |
Maximum Electrical Efficiency |
44.1 / 43.8% |
Maximum Standby Rating |
4500 ekW |
Frequency |
50 / 60 Hz |
RPM |
1000 / 900 rpm |
Engine Specifications
Engine Model |
CG260-16 |
Displacement |
16,586 in³ |
Aspiration |
TA |
Bore |
10 in |
Stroke |
13 in |
Generator Set Dimensions
Length |
371 in |
Width |
110 in |
Height |
133 in |
Dry Weight - Genset |
117,505 lb |
High Reliability
- Anti-knock control and cylinder balancing protect the engine from overload and ensure reliable operation
- State-of-the-art turbocharger A140 with Wastegate ensures full performance even under high temperatures and higher altitudes
- Higher reliability and lower maintenance costs due to open combustion chamber technology
High Availability, High Profitability
- Miller valve timing and optimized compression ratios ensure high efficiency and low fuels costs
- More profit for your plant
- Long maintenance intervals and general overhaul only after 80,000 oh allow an operation of 10 years without general overhaul
- Flexible fields of application also with fluctuating gas qualities due to Total Electronic Management (TEM)
Optimized Lubrication Consumption
- Savings of up to 4,000 liters of lube oil per year compared to comparable gensets<li>
- Improved components reduce lube oil consumption<li>
- Lower operating costs due to 30% lower lube oil consumption in comparison to similar products<li>
-
Air Inlet
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
-
Control Panels
- TEM (Total Electronic Management)
-
Cooling
- flange connections for JW inlet and outlet
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
-
Exhaust
- Exhaust waste gate for the CG260-16
- Closed crankcase ventilation system
-
Fuel System
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
-
Generator
- Busbar connections
- Closed-coupled generator result in no torque transmission to the base frame
- Reactive droop
- 3-phase sensing and KVAR/PF control
- Grid code generator
- Anti-condensation space heater
- Winding temperature detectors
-
Starting/charging
- Compressed air engine start
-
General
- Crankshaft vibration damper and guard
×