XQC1600

  • Exterior View
  • Exterior View

XQC1600

Rating 1515 ekW (1893 kVA) Continuous
Frequency 50/60 Hz
Voltage 230 - 480 V
IPP Overload 50Hz 1590 kW (1987 kVA)
Engine Cat 3516C
Fuel Diesel
Generator Set
Rating 1515 ekW (1893 kVA) Continuous
Frequency 50/60 Hz
Voltage 230 - 480 V
IPP Overload 50Hz 1590 kW (1987 kVA)
IPP Overload 60Hz 1790 kW (2237 kVA)
IPP Rated 60Hz 1705 kW (2131 kVA)
Engine
Engine Cat 3516C
Fuel Diesel
Dimensions
Height - Without Chassis 114 in
Length - Without Chassis 480 in
Weight - Without Chassis, With Fuel, Lube Oil and Coolant 70,000 lb
Width - Without Chassis 98 in
Generator
IPP Rated 60Hz 1705 kW (2131 kVA)

Rental Ready

Extensive range of rental ready features to meet job requirements and applications.

Fuel/Emissions Strategy

Low BSFC and Low Emissions* ratings, switchable via Cat Electronic Technician (ET)
* Does not conform to EPA/EU emissions standards

Reliable, Fuel Efficient Cat Diesel Engine

The compact, four-cycle Cat 3516C turbocharged-aftercooled (SCAC) diesel engine provides proven durability and dependability
Best-in-class fuel economy
Fuel system operates on a variety of fuels
50/60 Hz switchable with neither software re-flashing, nor iron changes required
Other engine features include: electric fuel priming, individual cylinder temperature monitoring, and extended filter change intervals

Cat EMCP Control Panel

EMCP 4.3 control panel offers engine and generator monitoring and protection
On-Package Auto Paralleling Controls
AGC-4 provides paralleling, load sharing, VFD control, and additional generator protection

Cat Generator

Cat SR5 generator designed to match the performance and output characteristics of the Cat Gas engine.
Class H insulation operating at Class F temperature for extended life
Coastal insulation protection and anti-condensation space heaters
Integrated Voltage Regulator (IVR) for fast response in demanding applications

Cooling System

Provides 49°C (120F) ambient capability at 50 Hz & 60 Hz
at the IPP Rating at 750m (2,460 ft) above sea level
Variable frequency fan drive with smart fan control
Energy efficient electric drive fans

Sound Attenuated Container

Meets 75 dB(A) (50 Hz) / 81 dBA (60 Hz) at 7m (23 ft)
40' ISO high cube container, 9-high stack CSC certified
Service and Personnel doors
Externally-accessible controls

Cat Connect

Remote monitoring for fleet management and asset tracking.

Reduced Environmental Impact

110% spill containment of onboard engine fluids
Positive crankcase fumes ventilation

Single-Source Supplier

Generator set manufactured in ISO 9001:2000 compliant facility
Package factory designed and production tested

Worldwide Product Support

Cat® dealers provide extensive post sale support including maintenance and repair agreements.
Supported 100% by the Cat dealer with warranty on parts and labor.
Extended Service Coverage (ESC) options available for coverage beyond the Standard Warranty period

  • Cat 3516c Heavy Duty Diesel Engine
    • Heavy duty, dual element, PowerCore air cleaners with service indicators
    • Triple, primary fuel filters with water separators and bypass valves for on-the-fly filters changes
    • Secondary fuel filters on engine
    • Full flow oil filters with water-cooled oil cooler. Requires API CI-4 or higher lube oil
    • Lubricating oil system includes make-up system (113-L tank), oil drain lines routed to the engine rail, and quick evacuation system for faster, cleaner oil changes
    • Jacket water heater (9 kW, 3-phase 480VAC) with electric pump
    • Fuel cooler and electric fuel priming pump
    • Electronic differential pressure monitoring of all filters
    • Electronic ADEM A4 engine controls
    • Dual 24V electric starting motors
  • Sr-5 Generator
    • Double-bearing, 1844-Frame, SR-5 generator with anti-condensation space heaters (1.2 kW, 480V)
    • Brushless, form-wound, permanent magnet excited, thouree-phase, 4-lead design
    • Class H insulation operating at Class F temperature for extended life
    • Cat Integrated Voltage Regulator (Cat IVR)
    • Stator winding and bearing temperature detectors monitored by RTD module
    • Metallic mesh generator air inlet filters (2)
    • System 4 insulation protection
  • 40' Iso High Cube Container
    • 9-High stackable, CSC certified
    • Sound attenuated, hinged, radiator intake louvers
    • Sound attenuated package air intake louvers with foldable awnings
    • Five (5) lockable personnel doors with panic releases
    • Interior walls and ceilings insulated with 100 mm of acoustic paneling
    • Side bus bar access door with external access load cable connections
    • Shore power via distribution block connections for jacket water heater, battery charger, space heaters, and generator Anti-condensation Heaters
    • Six (6) DC lights with 60-min timer
    • Single-wall, 946-L (250gal) fuel tank; certified to BS799-5
    • Solenoid fuel fill control valve for automated filling
    • Sound attenuated to 75 dB(A) (50Hz) 81 dB(A) (60Hz) at 7m (23 ft)
    • Four (4) 1400-CCA, Group 4D, maintenance-free batteries, and 50A battery charger
    • Insulated exhaust silencer with 1.8m (6ft) stainless steel exhaust stack for increased site power density
    • Engine vibration isolators
    • Easy drain access to standard fluids
    • Standard Cat decals (Optional) and painted Cat Power Module White
  • Cooling
    • Cooling package provides 49°C (120°F) ambient capability (50 & 60 Hz) at IPP Ratings @ 750m (2,460 ft)
    • Vertical, non-stacked radiator cores with dimpled fins and vertical air discharge
    • Variable frequency fan drive with smart fan control
    • Cat Extended Life Coolant (ELC)
  • Generator Controls And Protection
    • EMCP 4.3 generator set controller
    • Automatic start/stop with cool down timer
    • Generator Protection features: 25, 32, 40, 50/51, 27/59, 81 O/U
    • AGC-4 provides voltage and frequency adjust, base load / PF / load sharing / synchouronizer, auto start / stop control & generator CB control, SCADA Interface (Ethernet), fuel level indications & alarms, fuel tank fuel transfer control
    • Reverse compatibility for interface to legacy power modules
    • 100 kAIC, 4000A-Frame generator circuit breaker with LSIG trip unit
    • Multi-mode operation (Island (kW/kVAR sharing, Auto Mains Failure, Peak Shaving, Base Load Power, Export, zero power transfer, power management with multiple units)
    • Manual and automatic paralleling capability
    • Metering display: voltage, current, frequency, power factor, kW, WHM, kVAR, and synchouroscope
  • Quality
    • Factory testing of complete power module
    • CE Certified, NEMA, ISO and IEEE standards
    • O&M manuals
×