XQP1100 Rental Generator Set

Overview
Rating Prime
1100 kVA
Frequency
50/60 Hz
Voltage
127 - 480 V
  • Exterior View

Generator Set

Rating Prime
1100 kVA
Frequency
50/60 Hz
Voltage
127 - 480 V

Engine

Engine
C32 Diesel Engine
Fuel
Diesel

Dimensions

Width
96 in
Height
102 in
Length
240 in
Weight
35,088 lb
Weight - With Lube Oil and Coolant
32,053 lb

Fuel consumption Best Fuel Efficiency

100% Load 50Hz
58 gal/hr
100% Load 60Hz
67 gal/hr
75% Load 50Hz
43 gal/hr
75% Load 60Hz
50 gal/hr
50% Load 50Hz
31 gal/hr
50% Load 60Hz
134 l/hr

Noise rating (with enclosure) Best Fuel Efficiency

Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz)
84 dB(A)
Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz)
85 dB(A)

Rental ready

Robust, durable product with a range of rental ready features to meet job requirements and applications.

Fuel/Emissions Strategy

Best Fuel Efficiency.

Cat C32 Diesel Engine

Industry proven reliability.

Cat EMCP 4.4 Control Panel

Easy to use digital controls.

Cat SR500 Generator

Integrated voltage regular for fast response in demanding applications.

Robust Galvanised Enclosure

Inhibits corrosion in service. Prevents water ingress, provides security and sound attenuation.

Sound Isolated Operator Panel

Improved operator comfort.

Cat Connect

Remote monitoring for fleet management and asset tracking.

Factory Designed, Built and Tested

Single-source Supplier

World Wide Product Support

Supported by an industry leading global dealer network.

500 hr Oil Change Intervals

Reducing operating costs and producing less waste.

Improved Transportability

Drag bars, Lifting frame, Fork lift pockets and 4 point lift.

Additional Options Available

Synchronising controls.
Extended Service interval kits.

  • Cat C32 Diesel Engine
    • Turbo charged.
  • Generator
    • E3875L4 frame.
  • Air Filter
    • Cyclonic/paper with dust cup and service indicator.
  • Cat Connect Remote Monitoring
    • Provides package monitoring and management.
  • Cooling System
    • Package mounted radiator with vertical air discharge. Filled from factory.
  • Charging / Starting System
    • 24V heavy duty starting motor and charging alternator c/w battery isolator.
  • Fuel System
    • Fuel tank with 6 way directional valve for external supply.
  • Control Panel
    • Digital EMCP4.4 set mounted controller.
  • Distribution
    • Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off.
  • Structure
    • Heavy Duty steel base frame with integral fuel tank. Fork lift pockets. Dragging bars. Lifting frame and 4 point lift. Base frame is wider than enclosure to protect generator set during transportation.
  • Enclosure
    • Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance.
  • Exhaust
    • Integrated spark arresting silencer.
  • Lube Oil
    • On engine primary and secondary oil filters. Filled from factory.
  • General
    • Factory tested and inspected.
×