Dynamic Gas Blending System
- Achieves up to 70% substitution while maintaining dieselperformance and safe engine operation- Closed loop control system enables maximumsubstitution over the widest load range in the industry- Maintains traditional diesel generator set power andtransient response performance- Accepts a wide range of gas quality and automaticallyadjusts to fuel quality changes, eliminating the need forfield calibration- EMCP 4.4 control panel features simplified rig integration,remote monitoring capabilities, and single point interfacefor the engine, generator, and Dynamic Gas Blendingfunctions- Leverages current hardware from G3516 product linewhile minimizing change to core diesel engine- Maintains existing diesel maintenance and overhaulintervals proven in oilfield applications