Generator Set Specifications
Minimum Rating | 1760 ekW (2200 kVA) |
Maximum Rating | 1820 ekW (2275 kVA) |
Frequency | 50 Hz or 60 Hz |
Speed | 1000 rpm (50 hz) or 900 rpm (60 hz) |
Minimum Rating | 1760 ekW (2200 kVA) |
Maximum Rating | 1820 ekW (2275 kVA) |
Frequency | 50 Hz or 60 Hz |
Speed | 1000 rpm (50 hz) or 900 rpm (60 hz) |
Emissions/Fuel Strategy | EPA Tier 2, IMO II |
Generator Set Configurations
Emissions/Fuel Strategy | EPA Tier 2, IMO II |
Engine Specifications
Engine Model | In-line 6, 4-Stroke-Cycle Diesel |
Aspiration | Turbocharged-Aftercooled |
Bore | 11 in |
Stroke | 12 in |
Displacement | 6,773 in3 |
Governor Type | Electronic |
Fuel System | EUI |
Compression Ratio 50 Hz | 13 |
Compression Ratio 60 Hz | 13:1 |
Aspiration | Turbocharged-Aftercooled |
Bore | 11 in |
Stroke | 12 in |
Displacement | 6,773 in³ |
Governor Type | Electronic |
Engine Model | In-line 6, 4-Stroke-Cycle Diesel |
Generator Set Dimensions
Length | 280 in |
Width | 77 in |
Height | 155 in |
Weight (Estimated) | 18,000 lb |
Length | 280 in |
Width | 77 in |
Height | 155 in |
Weight - Estimated | 18,000 lb |