CG170B-16 Gas Generator Set
Continuous Rating |
1840 ekW @1.0pf |
Fuel Type |
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency |
44.70% |
Maximum Standby Rating |
1,840 |
Frequency |
50 Hz |
RPM |
1500 rpm |
Generator Set Specifications
Continuous Rating |
1840 ekW @1.0pf |
Fuel Type |
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency |
44.70% |
Maximum Standby Rating |
1,840 |
Frequency |
50 Hz |
RPM |
1500 rpm |
Engine Specifications
Engine Model |
CG170B-16 |
Aspiration |
TA |
Bore |
7 in |
Stroke |
8 in |
Generator Set Dimensions
Length |
240 in |
Width |
67 in |
Height |
86 in |
Dry Weight - Genset |
38,360 lb |
High Efficiency, Lower Operating Costs
- Up to 44.7% electrical efficiency with Natural Gas
- 43.6% electrical efficiency with biogas
- Electrical output up to 1,840 kWel
- Reduced vibration and stress on components
Compact Size, High Profitability
- Compact design that delivers up to 18% more power output at the same size as its predecessor
- Long maintenance intervals (up to 80,000 hours)
- Available in different applications, such as natural gas, biogas, wellhead- and propane gas operation
- Maximum flexibility through different engine variants
Optimized Lubrication Consumption
- Consumes ~0.15g/kWh
- Reduced lube oil temperature through better cooling performance
- Savings of up to 3,000 liters of lube oil per year compared to comparable gensets
-
Air Inlet
- Turbocharger with a water-cooled bearing case for all cylinder
- One-element single-stage air cleaner with enclosure and sevice indicator
-
Control Panels
- TPEM (Total Plant & Energy Management System)
-
Cooling
- flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
- Jacket water and SCAC thermostats
- ANSI/DN customer flange connections for JW inlet and outlet
-
Exhaust
- PEARL/Low resistence exhaust system
- Exhaust waste gate for the CG170B-16
- Closed crankcase ventilation system
-
Fuel System
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
-
Generator
- closed-coupled generator result in no torque transmission to the base frame
- Winding temperature detectors
- Busbar connections
- 3-phase sensing and KVAR/PF control
- grid code generator
- Reactive droop
- Anti-condensation space heater
-
Starting/charging
- 24V starting motors
- Battery disconnect switch
-
General
- Crankshaft vibration damper and guard
-
Cooling
-
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands
×