Single element canister style with service indicator
Aspiration
TA
Fuel System
Electronic unit injection
Bore
7 in
Displacement - HD
4,765 in³
Stroke - HD
Air Inlet
Single element canister style with service indicator
Exhaust Flange Size
203.2 mm (8.0 in)
Stroke
8 in
Displacement
4,765 in
Generator Set Specifications
Minimum Rating
2000 kVA
Maximum Rating
2500 kVA
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime, Continuous
Emissions/Fuel Strategy
Low Fuel, Low Emissions
Duty Cycle
Standby, Mission Critical, Prime, Continuous
Duty Cycle
Standby, Prime, Continuous, Mission Critical
Standby Rating
2500 kVA
Prime Power Rating
2275 kVA
Generator Set Dimensions
Height - Maximum
98 in
Length - Maximum
247 in
Width - Maximum
90 in
Dry Weight - Genset (maximum)
34,250 lb
Cat Generator Set Package
Cat generator set packages have been fully prototype tested
Accepts 100% block load in one step and meets NFPA 110 loading requirements
Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
Reliable, rugged, durable design
Field-proven in thousands of applications worldwide
Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
Superior motor starting capability minimizes need for oversizing alternator
Designed to match performance and output characteristics of Cat diesel engines
Robust Class H insulation
EMCP 4 Control Panel
User-friendly interface and navigation
Scalable system to meet a wide range of installation requirement
Expansion modules and site-specific programming for specific customer requirements
Cooling System
Designed to operate in standard ambient temperatures up to 50�C (122�F)
Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
EU Declaration of Conformity
EU Declaration of Incorporation
Eurasian Conformity
Telecommunication Lab of China
One Safe Source
Components used in the generator set are selected at the design stage to provide optimum package performance
The generator set is fully assembled at a Caterpillar facility following our quality guidelines
Each generator set package is tested before leaving the Caterpillar facility
Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
Cat dealers have over 1,800 dealer branch stores operating in 200 countries
Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Air Inlet System
Air cleaner; single element canister type
Control Panels
0 True RMS AC metering, 3-phase, +/-2% accuracy
Accessory module data link
Low oil pressure
1 Programmable relay outputs (Form C)
Reverse power (kW) (32)
Warning/shutdown with common LED indication of shutdowns for:
Environmental sealed front face
Programmable protective relaying functions:
kW-hr (total)
Auto/start/stop control
Generator set packages include Caterpillar's voltage
regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing,
KVAR/PF modes, RFI suppression, min/max exciter.
Limiter and exciter diode monitor
EMCP 4.2B
6 Customer programmable digital inputs
Load histogram feature
Emergency stop pushbutton
Reverse reactive power (kVAr) (32RV)
Customizable screens
Failure to start (overcrank)
kW (per phase, average & percent)
Low coolant level
PLC functionality
Communications:
kVAr-hr (total)
Engine cycle crank
Coolant temperature
kVA (per phase, average & percent)
Controls:
High coolant temperature
Generator phase sequence
Digital indication for:
Over/under frequency (81 o/u)
Number of I/O varies on options selected
Low coolant temperature
Alarm acknowledge
1 Programmable digital outputs
Amps (per phase & average)
Cat connect
Overspeed
Engine cool-down timer
Operating hours
Oil pressure (psi, kPa or bar)
RPM
Power factor (per phase & average)
Serial annunciator module data link
24 Volt DC operation
Overcurrent (50/51)
Generator mounted - rear facing
Over/under voltage (27/59)
3 Analog inputs
4 Programmable relay outputs (Form A)
Speed adjust
Text alarm/event descriptions
kVAr (per phase, average & percent)
Customer data link (Modbus RTU)
Frequency (Hz)
Volts (L-L & L-N)
DC volts
Lamp test
Cooling System
Certified standard PGS provided
Exhaust System
Flanged faced outlet(s)
Dry exhaust manifold
Fuel System
Fuel cooler; not included with packages without radiator
Flexible fuel lines - shipped loose
Secondary fuel filters
Fuel priming pump
General
Flywheel and flywheel housing - SAE No. 00
SAE standard rotation
Caterpillar yellow with high gloss black rails and radiator
Right hand servicing
Generator And Attachments
Low voltage:
Busbar connections, right side extension box, bottom cable entry
Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
NEMA standard hole pattern
Internal excitation (IE)
Random wound
Anti-condensation space heater
Winding temperature detectors
Form wound
6 Leads
High voltage:
Medium voltage:
3 Phase brushless, Salient pole
Permanent magnet excitation (PMG)
NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
Busbar connections, top center mounted, top cable entry
Governing System
ADEM A3
Literature
Parts book
Lubrication System
Oil drain lines and valve
Fumes disposal
Oil filter, filler and dipstick
Lubricating oil
Gear type lube oil pump
Integral lube oil cool
Mounting System
Rails - Engine/generator/radiator mounting
Rubber anti-vibration mounts - shipped loose
Anti-vibration mounts (shipped loose)
Starting System
Battery and battery rack w/cables
24 Volt electric starting motor
45 Amp Charging alternator
Battery disconnect switch
Control System
EMCP 4.4
Local annunciator module: [ ] NFPA 110 [ ] Custom
Engine Options
Starting aids: 220V 50 Hz Jacket water heater
Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
Starting motors: [ ] Standard [ ] Heavy duty
Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners