C15 (50 Hz) China Non Road
Bore |
5 in |
Displacement |
928 in³ |
Stroke |
7 in |
Aspiration |
Air to Air Aftercooled |
Fuel System |
MEUI |
Minimum Rating |
365 kVA |
Engine Specifications
Bore |
5 in |
Displacement |
928 in³ |
Stroke |
7 in |
Aspiration |
Air to Air Aftercooled |
Fuel System |
MEUI |
Engine Model |
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
Compression Ratio |
16.1:1 |
Governor Type |
Adem™A4 |
Aspiration |
Air to Air Aftercooled |
Fuel System |
MEUI |
Bore |
5 in |
Displacement |
928 in³ |
Stroke |
7 in |
Fuel System |
7 in |
Generator Set Specifications
Minimum Rating |
365 kVA |
Maximum Rating |
550 kVA |
Voltage |
208 to 600 Volts |
Frequency |
50 Hz |
Speed |
1500 rpm |
Emissions/Fuel Strategy |
Low Fuel, Tier 2 or 3 |
Duty Cycle |
Standby, Prime |
Generator Set Dimensions
Height - Maximum |
93 in |
Length - Maximum |
223 in |
Width - Maximum |
90 in |
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
-
Air System
- Aftercooler core
- Turbocharger
- Air Cleaner - Non Canister disposable paper filter
-
Air Inlet
-
Control Panel
- EMCP 4.2
- EMCP 4 Genset Controller
-
Cooling
-
Cooling System
- Radiator and cooling fan with guard
- Coolant drain line with valve
- Caterpillar Extended Life Coolant
- Fan drive, battery charging alternator drive
-
Fuel
- Secondary fuel filter
- Fuel priming pump
- Primary fuel filter with integral water separator
-
Exhaust
- Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange
for customer use; shipped loose
- Exhaust flange outlet
-
Fuel System
- Standard open set fuel tank / base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
-
Generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
-
Generator And Attachments
- IP23 Protection
- A frame generator - IP21 Protection
- Segregated low voltage (AC/DC) wiring panel
- Mandatory Option circuit breaker, IEC, 3 pole, mounted in power
- Optional LC frame generator - IP23 Protection
- Power center, IP22
- Integrated Voltage Regulator
-
Power Termination
-
Governing System
- Cat Electronic Governor (ADEM A4)
-
Lube System
- Lubricating oil
- Oil drain valves
-
Mounting
- Rubber vibration isolators
-
Mounting System
- Rubber vibration isolators
-
Starting/charging
- 24 Volt battery with rack and cables
- Batteries
- 24 volt starting motor
-
General
- Engine and alternator pre paint, Caterpillar yellow
- Paint - Caterpillar Yellow except rails and radiators gloss black
-
Air Inlet System
- Single element air cleaner
- Dual element air cleaner
-
Exhaust
- Industrial, Residential, Critical Mufflers
-
Certifications
- EU certificate of conformance
- Global certification for CIS
-
Generator
- Oversize and premium generators
- Anti-condensation heater
- Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
-
Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
-
Circuit Breakers
- 4 Pole (IEC-100% rated) circuit breakers - Motorised
- 3 Pole (IEC-100% rated) circuit breakers - Motorised
- Auxiliary contacts, circuit breaker
- 4 Pole (IEC-100% rated) circuit breakers - Package mounted
- Pad-lockable circuit breaker device
- Power terminal strip
- Shunt trip for IEC circuit breaker
- 3 Pole (IEC-100% rated) circuit breakers - Package mounted
-
Control Panels
- Protective devices: Earth fault relay ; Earth leakage ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
- Remote annunciator
- Oil temperature displays
- EMCP 4.3, EMCP 4.4
- Local annunciator
- Local alarm horn
- Volt free contacts
-
Starting/charging
- Jacket water heater
- Heavy-duty starting system
- Battery chargers
- Oversize batteries
- Charging alternator
-
Cooling System
- Radiator duct flange
- Stone guards
- Low coolant temperature alarm
-
Enclosures
- Sound attenuated enclosures
- High ambient sound attenuated enclosures
-
Exhaust System
- End in / End out mufflers - 10, 25 and 35 dBA attenuation
- Manifold and turbocharger guard
- Flexible exhaust fittings
- 6 and 8 inch flange GP
- 6 and 8 inch elbow kit
- Engine mounted muffler
-
Fuel System
- Dual wall fuel tank base
- Manual fuel transfer pump
- Fuel transfer system controls
-
General
- UL 2200 package
- Automatic transfer switches (ATS)
- Narrow, Wide or Skid Base
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- Single or dual wall sub-base fuel tanks
- EU Certificate of Conformance (CE)
- EEC Declaration of Conformity
- The following options are based on regional and product configuration:
- Single or dual wall integral fuel tanks
- CSA Certification
- Sound attenuated, weather protective or high ambient weather protective enclosure
- Integral & sub-base UL listed dual wall fuel tanks
-
Generator And Attachments
- Oversize A frame generator
- LC frame generator
- Oversize LC frame generator
- CIP a frame generator
- LC frame CIP generator
- Permanent magnet generator
- Space heaters
- Ingress protection
-
Lube System
-
Mounting System
- Narrow skid base - replaces standard fuel tank base
-
Special Test / Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
-
Starting / Charging System
- 5 Amp single battery charger
- Battery disconnect switch
×