CG132B-8 Gas Generator Set
| Continuous Rating |
400 ekW @1.0pf |
| Fuel Type |
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
| Maximum Electrical Efficiency |
43.1% / 42.1% |
| Frequency |
50 / 60 Hz |
| RPM |
1500 or 1800 rpm |
| Engine Model |
CG132-8 |
Generator Set Specifications
| Continuous Rating |
400 ekW @1.0pf |
| Fuel Type |
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
| Maximum Electrical Efficiency |
43.1% / 42.1% |
| Frequency |
50 / 60 Hz |
| RPM |
1500 or 1800 rpm |
Engine Specifications
| Engine Model |
CG132-8 |
| Displacement |
1,068 in³ |
| Aspiration |
TA |
| Bore |
5 in |
| Stroke |
6 in |
Generator Set Dimensions
| Length |
122 in |
| Width |
70 in |
| Height |
85 in |
| Dry Weight - Genset |
12,610 lb |
High Efficiency, Lower Operating Costs
- Highest efficiency in its output class
- Up to 42.5% improved electrical efficiency
- Reduced vibration and stress on components
Low installation, Building and Operating Costs
- Compact design with integrated fuel tanks for daily refilling
- Lower setup costs than comparable engines
- Reduced investment costs through expanses product scope and TPEM digital control system
- Long maintenance intervals (up to 80,000 hours)
- Optimized oil management
Optimized Lubrication Consumption
- Consumes less than 0.1g/kW of oil
- Up to 66% lower lubricant consumption than comparable models
- Longer lubricant change (up to 4,000 hours) and oil change intervals
-
Air Inlet
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
-
Control Panels
- TPEM (Total Plant & Energy Management System)
-
Cooling
- flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
- Jacket water and SCAC thermostats
- ANSI/DN customer flange connections for JW inlet and outlet
-
Exhaust
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
-
Fuel System
- Independently controlled cylinder monitoring and ignition system
- Electronic fuel metering valve
- Pre-chamber spark plugs
-
Generator
- Anti-condensation space heater
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Winding temperature detectors
- Busbar connections
- 3-phase sensing and KVAR/PF control
- grid code generator
-
Starting/charging
- 24V starting motors
- Battery disconnect switch
-
General
- Crankshaft vibration damper and guard
-
Cooling
-
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands
×