C18 Marine Generator Set

  • Exterior View

C18 Marine Generator Set

Minimum Rating 260 ekW (325 kVA)
Maximum Rating 565 ekW (706 kVA)
Frequency 50 hz
Speed 50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Configuration In-line 6, 4-Stroke-Cycle Diesel
Aspiration Turbocharged - aftercooled
Generator Set Specifications
Minimum Rating 260 ekW (325 kVA)
Maximum Rating 565 ekW (706 kVA)
Frequency 50 hz
Speed 50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Minimum Rating 260 ekW (325 kVA)
Maximum Rating 565 ekW (706 kVA)
Frequency 50 / 60
Speed 50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Engine Specifications
Configuration In-line 6, 4-Stroke-Cycle Diesel
Aspiration Turbocharged - aftercooled
Bore 6 in
Stroke 7 in
Fuel System MEUI
Configuration In-line 6, 4-Stroke-Cycle Diesel
Aspiration Turbocharged - Aftercooled
Bore 6 in
Stroke 7 in
Oil Change Interval 250 / 500 hours
Governor Electronic
Refill Capacity 68
Cooling Heat Exchanger, Keel, Radiator Cooled
Rotation from Flywheel End SAE No. (136 teeth)
Generator Set Dimensions (Keel and Hex Cooled)
Length 120 in
Height 65 in
Generator Set Dimensions (Radiator Cooled)
Length 56 in
Height 95 in
Generator Set Configurations
Emissions EPA Tier 3, IMO II, EU IWW, EU Stage V, China II
Generator Specifications
Excitation SRMP
Insulation Class H
IP Rating IP23 (standard), IP 44 (optional)
Voltage Regulator CDVR (Digital Voltage)
Generator Set Dimensions - Keel and Hex Cooled
Width 56 in
Weight - Approximate 9,747 lb
Height 65 in
Length 120 in
Generator Set Dimensions - Radiator Cooled
Width 67 in
Weight - Approximate 13,396 lb
Height 95 in
Length 56 in
Power Rating
Power Range 260 - 565 ekW

Separate circuit aftercooling system

The primary advantage of the separate circuit aftercooling system (SCAC) is that no sea water circulates through the aftercooler

Emissions

EPA Tier 3 compliant, IMO II and EU IWW compliant

Cooling system

Heat exchanger and Keel cooled options for all ratings

Turbo Configurations

Single turbo configurations for all ratings

Competitive size and weight

Marine Certifications

All major MCS type approvals available from factory

  • Air Inlet System
    • Separate circuit after-cooled (SCAC)
    • Open Crankcase Ventilation (OCV) system
    • Turbocharger, jacket water cooled
    • Turbocharger inlet, 152 mm (6 in) OD straight connection
  • Cooling System
    • SCAC pump, gear driven, for HEX cooled engines only
    • Jacket water pump, gear driven
    • SCAC and JW shunt tanks for maintaining proper pump inlet pressures
  • Exhaust System
    • Water-cooled exhaust manifold & turbocharger
    • Round flanged exhaust outlet
  • Fuel System
    • Hybrid fuel line design
    • Fuel transfer pump, gear driven
    • Front service simplex fuel system
    • Manual fuel priming pump
  • Lube System
    • Center sump oil pan: Deep 500 hour oil change interval
    • Front and top service oil filler locations
    • Front service dipstick
  • Lube System
    • Oil pump, gear driven
  • Mounting System
    • Vibration Isolators
    • Formed C-channel rails
  • Control System
    • Common Interface to all Genset Control Panels
    • Programmable Low Idle
    • Electronic Diagnostics and Fault Logging
    • Electronic Fuel/Air Ratio Control
  • Control System
    • Programmable ECM Shutdowns for: High Jacket Water Coolant Temp Low Engine Oil Pressure Engine Overspeed
  • Exhaust System
    • Dry Elbows
    • Water-Cooled Elbows
    • Flexible Fitting
    • Flange
    • Muffler
    • Muffler, Spark Arresting
  • Air Inlet System
    • Air Inlet Adapter
  • Charging System
    • Battery Chargers 10 amp
    • Charging alternator 24V 105 amp
  • Control System
    • Caterpillar alarm and protection
    • EMCP 4.2 control panel
    • MGCP III B control panel
  • Fuel System
    • Duplex fuel filter – front service
    • Fuel cooler
    • Primary fuel/water separator
  • Instrumentation
    • Generator service side - LH, RH
    • Generator terminal box extension
    • Load sharing module (option for type approved module)
  • Lube System
    • Duplex oil filter
    • Sump pump
  • Protection System
    • Generator protection - IP44
  • Starting System
    • Starting motors - electric and/or air
    • Jacket water heaters
×